Ultrapure dialysate: facts and myths

Juergen Bommer1, Bertrand L Jaber

  • 1Department of Internal Medicine, University of Heidelberg, Heidelberg, Germany. juergen_bommer@t-online.de

Seminars in Dialysis
|March 23, 2006
PubMed

During hemodialysis, blood comes in contact with a large volume of dialysate. Since the purity of dialysate has been linked to acute and long-term complications in hemodialysis patients, the limit of bacterial and endotoxin contamination has been reduced in recent years. Questions have been raised as to whether ultrapure dialysate is required to prevent such complications; in particular, the chronic inflammatory status frequently found in chronically hemodialyzed patients. In vivo and in vitro data suggest that cytokine stimulation in the blood depends on the concentration of bacteria or endotoxin in the dialysate and on the endotoxin permeability of the dialysis membrane. It is not proven whether ultrapure dialysate reduces significantly proinflammatory cytokine generation compared with standard dialysate within the limits of recent recommendations, if rather impermeable dialysis membranes are used. Cuprophane membranes are more permeable to cytokine-inducing substances compared with synthetic membranes such as polysulfone and polyamide. Clinical reports have also attempted to link several acute and chronic complications of hemodialysis to dialysate purity. To date, however, there is no large randomized clinical trial demonstrating that ultrapure dialysate significantly reduces biomarkers of inflammation and other consequential putative complications, including dialysis-related amyloidosis, erythropoietin requirement, and cardiovascular morbidity and mortality. In conclusion, based on the existing clinical data, ultrapure dialysate is recommended in the setting of suboptimal bacteriologic quality of standard dialysate and the use of permeable dialysis membranes.

Related Concept Videos

Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
Dialysis01:27

Dialysis

Renal failure occurs when the kidneys lose their ability to filter waste products from the blood effectively. It can be classified into two types: acute renal failure (ARF) and chronic renal failure (CRF).
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Peritoneal Dialysis I: Introduction and Procedure01:30

Peritoneal Dialysis I: Introduction and Procedure

Peritoneal dialysis (PD) is a procedure that facilitates the exchange of solutes, waste products, electrolytes, and excess fluid between the blood in the peritoneal capillaries and a dialysis solution introduced into the peritoneal cavity.Principles of Peritoneal Dialysis (PD)Diffusion: Waste products such as urea and electrolytes move from high concentrations in the blood to low concentrations in the dialysate across the peritoneal membrane. This mechanism is driven by the concentration...
Formation of Dilute Urine01:20

Formation of Dilute Urine

The formation of dilute urine is a critical renal adaptation that maintains fluid balance, particularly during periods of high fluid intake. This process primarily involves the juxtamedullary nephrons. By adjusting the permeability of water and ions in response to physiological conditions, the kidneys can either conserve or excrete water, resulting in concentrated or dilute urine.
Filtrate Osmolarity in the PCT
Initially, as the filtrate passes through the proximal convoluted tubule (PCT), its...
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications01:25

Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications

Peritoneal dialysis (PD) is a medical process that removes waste products and excess fluid from the body using the peritoneal membrane as a natural filter.Peritoneal Dialysis MethodsSeveral methods can be used for peritoneal dialysis, including Acute Intermittent Peritoneal Dialysis, Continuous Ambulatory Peritoneal Dialysis, and Automated Peritoneal Dialysis, also known as Continuous Cyclic Peritoneal Dialysis.Acute Intermittent Peritoneal Dialysis (AIPD) is used for patients with uremic...