Related Experiment Video
Updated: Mar 2, 2026

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Comparison of different patient positioning strategies to minimize shoulder girdle artifacts in head and neck CT
Stefan Wirth1, Thomas Meindl, Marcus Treitl
1Department of Clinical Radiology, University of Munich, Nussbaumstr. 20, 80336 Munich, Germany. swirth@med.uni-muenchen.de
Abstract:
The purpose of this study was to analyze different patient positioning strategies for minimizing artifacts of the shoulder girdle in head and neck CT. Standardized CT examinations of three positioning groups were compared (P: patients pushed their shoulders downwards; D: similar optimization by a pulling device; N: no particular positioning optimization). Parameters analyzed were the length of the cervical spine not being superimposed by the shoulder girdle as well as noise in the supraclavicular space. In groups P and D, the portion of the cervical spine not superimposed was significantly larger than in group N (P: 10.4 cm; D: 10.6 cm; N: 8.5 cm). At the supraclavicular space, noise decreased significantly (P: 12.5 HU; D: 12.1 HU; N: 17.7 HU). No significant differences between the two position-optimized groups (P and D) were detected. Optimized shoulder positioning by the patient increases image quality in CT head and neck imaging. The use of a pulling device offers no additional advantages.
More Related Videos
06:09Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...