Absolute counting of 188Re radiopharmaceuticals
Ming-Chen Yuan1, Hsiao-Fang Pang, Chu-Fang Wang
1National Radiation Standard Laboratory, Institute of Nuclear Energy Research, No. 1000, Wunhua Rd., Jiaan Village, Longtan Township, Taoyuan County 32546, Taiwan, ROC. mcyuan@iner.gov.tw
Abstract:
The Institute of Nuclear Energy Research (INER) has provided 188Re radiopharmaceuticals for hospitals in Taiwan. To enhance the accuracy of commercial radionuclide calibrators used by radiopharmacies and hospitals, and to ensure that patients receive proper doses of these radiopharmaceuticals, it is very important to standardize this nuclide. The 4pibeta-gamma coincidence counting method was used to standardize the mass activities of 188Re in this study. At the same time, three well type ionization chambers, Centronic IG11-N20, Centronic IG11-A20, and ISOCAL-IV, were calibrated by the standardized solutions of the nuclide. In this research, the calibration figures of ISOCAL-IV for the nuclide were consistent with the results of National Physical Laboratory (NPL, UK). The outcome implied that the results of coincidence counting did mutually agree. On the other hand, the radionuclide calibrator in the radiopharmacy was producing measurement errors of about 20% when using the manufacturers recommended calibration setting: an accurate correction factor has now been determined in this study.
More Related Videos
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
09:08Enhancing Efficiency and Radiolabeling Yields of Carbon-11 Radioligands for Clinical Research Using the Loop Method
Published on: December 20, 2024
Related Concept Videos
Radioactivity and Nuclear Equations
A nuclide of an element has a specific number of protons and...
Nuclear Stability
To hold positively...
Nuclear Transmutation
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Isotopes and Radioisotopes
An isotope containing...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET