Related Experiment Video
Updated: Aug 9, 2026

Characterizing Microbiome Dynamics – Flow Cytometry Based Workflows from Pure Cultures to Natural Communities
Published on: July 12, 2018
Comparison between direct microscopy and flow cytometry for rRNA-based quantification of Candidatus Accumulibacter
Rafael Perez-Feito1, Jordan Peccia, Daniel R Noguera
1Department of Civil and Environmental Engineering, University of Wisconsin-Madison, USA.
Abstract:
A comparison of the quantification of a specific microbial group in activated sludge by fluorescent in-situ hybridization, coupled with either direct microscopic counting or flow cytometry, was performed using an enhanced-biological-phosphorus-removal, sequencing-batch reactor. The population dynamics of Candidatus Accumulibacter phosphatis (Cand. A. phosphatis) was evaluated during two separate runs of the reactor. With the operational conditions used, Cand. A. phosphatis was enriched until a failure in the pH controller eliminated its ecological advantage. As a result, the comparison of quantification techniques included Cand. A. phosphatis concentrations as low as 11% and as high as 96% of the total cells in the samples. The analysis demonstrated that, regardless of the particular limitations of each technique, both provided similar results when the activated-sludge flocs were easily dispersed. However, when the activated-sludge samples contained flocs that were difficult to disperse, flow cytometry failed to provide quantitative results.
Related Concept Videos
Flow Cytometry
In...
Methods to Assess Microbial Populations