Related Experiment Video
Updated: Aug 4, 2026

4D Multimodality Imaging of Citrobacter rodentium Infections in Mice
Published on: August 13, 2013
Tagging-based, electronically cleansed CT colonography: evaluation of patient comfort and image readability
Michael E Zalis1, James J Perumpillichira, Cordula Magee
1Division of Abdominal Imaging and Interventional Radiology, Department of Radiology, Massachusetts General Hospital, White 270, 55 Fruit Street, Boston, MA 02114, USA. mzalis@mgh.harvard.edu
Purpose:
To prospectively compare the homogeneity, adequacy, and patient acceptance of nonionic iodine-based regimens with those of a barium-based regimen for computed tomographic (CT) colonography with electronic subtraction cleansing.
Materials And Methods:
After institutional review board approval and informed consent were obtained, 68 subjects (41 men (60%) men, 27 (40%) women; mean age, 60 years +/- 6 [standard deviation]) with average or moderate risk factors for development of colorectal carcinoma were recruited and placed into three study groups. Group 1 (n = 25) ingested 150-mL aliquots of 2% barium sulfate suspension with meals and snacks for 48 hours prior to imaging, without other diet modification or a cathartic. Group 2 (n = 21) ingested 10-mL aliquots of nonionic iodinated contrast material (iopromide) with a concentration of 300 mg per milliliter with meals and snacks for 2 days before imaging, without diet modification or a cathartic. Group 3 (n = 22) ingested nonionic iodinated contrast material (iohexol) with a concentration of 300 mg per milliliter with meals and snacks for 2 days before imaging and ingested 34 g of magnesium citrate the evening prior to imaging. CT colonography was also performed on 10 control subjects who ingested polyethylene glycol electrolyte solution prior to imaging. Subjective and numerical measures of bowel preparation quality, homogeneity, and patient comfort among the noncathartic and cathartic cohorts were compared with nonparametric analysis of variance, the Fisher exact test, and the F test, as appropriate. The study was HIPAA compliant.
Results:
Study subjects who received tagging preparations reported significantly improved discomfort scores when compared with those of the control subjects (P < .05, each comparison). There was no significant difference in discomfort scores among groups 1, 2, and 3. For each reader, scores of subtracted image readability were highest for group 3. Dichotomized rates of preparation "success" were also greatest for group 3.
Conclusion:
In this series, the patient discomfort scores were significantly improved with tagging preparations for CT colonography. Nonionic iodinated contrast material in conjunction with a hyperosmotic laxative (magnesium citrate) was associated with the best subjective and numerical indices of readability.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography

