Related Experiment Video
Updated: Aug 9, 2026

In Vivo Telemetry to Record Long-Term Cardiovascular Parameters, Temperature, and Activity in Spinal Cord Injury Rat Models
Published on: January 2, 2026
Unstable baseline blood pressure in chronic tetraplegia
1Spinal Cord Injury and Medical Services, Department of Veterans Affairs Medical Center, 1400 Veterans of Foreign Wars Parkway, West Roxbury, MA 02132, USA.
Study Design:
Case-control.
Objective:
Tetraplegic patients are subject to episodes of autonomic dysreflexia and postural hypotension. It is suggested that these patients sustain, in addition, unstable baseline blood pressure (BP) that is independent of symptoms and body position.
Methods:
BP monitoring was conducted in 10 tetraplegic patients, motor and sensory complete (American Spinal Injury Association (ASIA) A) (Group A), and five paraplegic at T8-T10 levels, ASIA A (Group B). A SpaceLabs automatically inflating pneumatic cuff recorded arm pressures at 10-30 min intervals in the daytime, sitting position and at 30 min intervals in the night-time, recumbent position. Group mean arterial pressure (MAP) and MAP standard deviation (MAP variation) for sitting and recumbent positions were compared.
Results:
Sitting the MAP for Group A was less than that of Group B; 87+/-9 versus 108+/-7 mmHg, P<0.01. However, MAP variability for Group A was greater than for Group B; 17+/-4 (20% of MAP) versus 13+/-2 mmHg (12% of MAP), P=0.04. In the recumbent position, the MAP for Group A was similar to that for Group B; 87+/-13 versus 97+/-7 mmHg, P=0.16. However, MAP variability for Group A remained higher than for Group B; 13+/-3 (20% of MAP) versus 8+/-2 mmHg (8% of MAP), P=0.02.
Conclusion:
Tetraplegic patients demonstrate unstable BP in either the sitting or recumbent position compared with low thoracic paraplegic patients.
More Related Videos
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
06:51Development of an Algorithm to Perform a Comprehensive Study of Autonomic Dysreflexia in Animals with High Spinal Cord Injury Using a Telemetry Device
Published on: July 29, 2016
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart beats)...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure in the Leg
Preparation:
Errors occurring during blood pressure monitoring
Several factors...