Related Experiment Videos
Stereotaxic localization for fine-needle aspiration breast biopsy. Initial experience with 300 patients
J S Mitnick1, M F Vazquez, D F Roses
1Department of Radiology, Kaplan Cancer Center, Tisch Hospital, New York, NY.
Abstract:
The efficacy of stereotaxic aspiration biopsy was evaluated in 300 consecutive patients with nonpalpable mammographic lesions. Sixty-eight patients (23%) had suspicious or malignant aspirates; all cases were proved malignant by subsequent examination of operative specimens. Two hundred sixteen patients (72%) had benign aspirates. Of these, 65 were confirmed by operation and 151 had subsequent mammography at 6- and 12-month intervals with no demonstrable mammographic change. In 10 instances (3%), the aspirates were atypical, and in six (2%), nondiagnostic. Biopsy specimens were obtained in all 16 instances, and eight were malignant. The sensitivity of stereotaxic breast aspiration for the diagnosis of cancer was 96%, and the specificity was 100%. Our experience confirms the efficacy of stereotaxic aspiration for the initial evaluation of mammographically detected, nonpalpable lesions.