Antenatal umbilical coiling index and Doppler flow characteristics
M Predanic1, S C Perni, F A Chervenak
1Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Weill Medical College of Cornell University, New York, NY 10021, USA. mlp2001@med.cornell.edu
Umbilical cord coiling impacts fetal blood flow, with higher coiling (umbilical coiling index) potentially offering protection by reducing resistance and increasing flow. However, clinical significance remains uncertain due to limited differences across coiling groups.
Area of Science:
- Perinatology
- Fetal Medicine
- Medical Imaging
Background:
- The umbilical cord's structure, including coiling, is crucial for fetal development.
- Variations in umbilical cord coiling may influence fetal well-being and placental function.
Purpose of the Study:
- To investigate the association between antenatal umbilical coiling index (UCI) and umbilical cord Doppler flow parameters.
- To determine if umbilical cord coiling patterns correlate with fetal blood flow characteristics.
Main Methods:
- Prospective study of 200 pregnant patients at 18-23 weeks' gestation.
- Umbilical coiling patterns and Doppler flow (umbilical vein flow, umbilical artery resistance index [RI], peak systolic velocity [PSV]) were assessed.
- Antenatal umbilical coiling index (UCI) calculated as reciprocal of inter-coil distance.
Main Results:
- 154 patients included; mean antenatal UCI was 0.40.
- Significant correlations found between antenatal UCI and umbilical artery RI, PSV, and umbilical vein blood flow volume.
- Lower RI and higher PSV/umbilical vein flow associated with higher antenatal UCI (P=0.016, P<0.001, P=0.032).
- Only PSV showed significant differences when stratified into hypo-, normo-, and hypercoiled groups (P=0.016).
Conclusions:
- Umbilical cord coiling appears to modulate umbilical cord blood flow.
- Increased coiling (higher UCI) may protect blood flow by decreasing resistance and increasing velocity/volume.
- Clinical implications are uncertain due to lack of significant Doppler differences across stratified coiling groups.