Inadvertent lumbosacral plexopathy due to temporary pacemaker implantation
Firat Ozcan1, Yesim Güray, Levent Ozçakar
1Yüksek Ihtisas Hospital, Department of Cardiology, Ankara, Turkey.
Journal of the National Medical Association
|April 1, 2006
Abstract:
Reported here is a 70-year-old man who suffered from a lumbosacral plexopathy after a temporary pacemaker implantation. Drawing attention to the increased number of femoral catheterizations in cardiovascular practice, we have highlighted some neuromuscular complications pertaining to these type of interventions.