Related Experiment Video
Updated: Aug 9, 2026

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Postoperative tracheal rupture in a patient with a difficult airway
1Department of Anesthesia, University Health Network, Toronto General Hospital, 200 Elizabeth Street, Eaton North Wing, 3rd Floor, Room 424, Toronto, Ontario M5G 2C4, Canada. pcmacdou@dal.ca
Purpose:
Tracheal rupture is an uncommon and potentially life-threatening event. This report presents a case of postoperative tracheal rupture in a patient with a known difficult airway presenting to a rural hospital.
Clinical Features:
A 29-yr-old man presented to a rural hospital with sudden onset neck pain and progressive dyspnea. Five days earlier the patient had undergone tracheal resection for tracheal stenosis related to prolonged intubation. The patient informed the emergency room staff that the attending anesthesiologist had made note of a "difficult airway". The community hospital had neither a portable storage unit for difficult airway management nor a bronchoscope available. In the presence of a general surgeon, an initial attempt at an awake intubation was unsuccessful. During this time the patient developed massive subcutaneous emphysema obliterating surgical landmarks and causing stridor. A modified rapid sequence intubation was performed. Intubation was successful using a Jackson-Wisconsin #3 straight blade and styletted endotracheal tube. The patient was transferred to a tertiary care centre where he underwent a primary repair of the trachea.
Conclusion:
Management of tracheal rupture in the patient with a difficult airway is a challenging problem, especially, in a rural hospital. This case highlights the need for skilled staff and resources to manage a difficult airway in the emergency room.
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of the...