Related Experiment Video
Updated: Aug 9, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
[Whole-body MR angiography: comparison of two protocols for contrast media injection]
Purpose:
To compare two injection strategies for contrast media injection in whole-body MR angiography quantitatively and qualitatively with regard to contrast and image quality.
Material And Methods:
40 patients were examined at 1.5 Tesla using either a single injection protocol or a double injection protocol with two separate bolus injections. Vessel regions I (supraaortic/thoracic), II (abdominal/pelvic), III (upper legs) and IV (lower legs) were examined in the following order: single injection: I, II, III, IV, double injection: I and IV after the first injection, II and III after the second bolus injection. Quantitative evaluation: SI measurements were carried out in 2 arteries per region. Contrast values were calculated. Qualitative evaluation: Evaluation of regions I-IV regarding vessel contrast, venous overlay and image quality on a five-point scale by two reviewers in consensus. The Mann-Whitney-U test was used to test the differences for significance.
Results:
Quantitative evaluation: Using the double injection protocol, significantly higher contrast values in regions I and II and significantly lower contrast values in the subregions IIIa (upper part of III) and IVb (lower part of IV) were obtained (p < 0.05). The mean contrast values in subregions IIIb (lower part of III) and IVa (upper part of IV) were lower using the double injection protocol, but not significantly. Qualitative evaluation: Using the double injection protocol, region II was rated significantly higher (mean ratings: 3.55, 3.45 and 3.5 versus 2.7, 2.5 and 2.55; p < 0.05) and region III significantly lower (mean ratings: 3.1, 2, 2.5 versus 3.9, 3.1 and 3.55; p < 0.05) for all three examined criteria. When using the double injection protocol, ratings were significantly lower in region IV regarding vessel contrast and image quality (mean ratings: 2.4 and 2.15 versus 3.45 and 3.15; p < 0.05). The ratings regarding venous overlay in region IV showed no significant differences (mean ratings: 2.15 versus 2.75; p > 0.05).
Conclusion:
Due to the better results in the supraaortic/thoracic and abdominal/pelvic regions, the double injection protocol is preferred. However, both protocols require further improvement.
More Related Videos
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

