Related Experiment Video
Updated: Aug 17, 2026

Dynamic Electrochemical Measurement of Chloride Ions
Published on: February 5, 2016
Chloride-related current fluctuation in amphibian skin
1Physiologisches Institut, Universität München, Federal Republic of Germany.
Abstract:
Fluctuation in transepithelial current was analysed in skins of Rana esculenta and Bufo viridis. Perturbation of the tissues to serosa + 40 mV or + 80 mV activated a pathway for conductive Cl transport and led to the appearance of a Lorentzian component in the power density spectrum. The presence of Cl on the mucosal side was mandatory for the observation of Lorentzians. Corner frequencies, fc, ranged between 48 Hz and 102 Hz. The mean value was slightly larger at 40 mV than at 80 mV (88.3 +/- 4.4 versus 72.5 +/- 6.4 Hz). Plateau values, So, were proportional to the magnitude of the activated Cl current. Single-channel currents of 48.3 +/- 5.2 fA and 93.0 +/- 8.7 fA were calculated at 40 mV and 80 mV, respectively, with the assumption of equal open and closed probabilities of the channels. From these data, a voltage-dependent open-channel conductance of about 1.2 pS is obtained. Activation of Cl conductance was associated with an increase in channel density. Stimulation of Cl conductance by procaine did not affect So and fc despite considerable stimulation of transepithelial Cl current. This could indicate that non-gated channels participate in the voltage-sensitive Cl conductance. Mucosal application of inhibitors of Cl conductance (3',5-dichlorodiphenylaminocarboxy acid, MK-196) decreased So in a concentration-dependent manner, but had no effect on fc. The data could support the hypothesis that the voltage-sensitive transepithelial Cl transport is localized to a cellular compartment, which is most likely the mitochondria-rich cells.(ABSTRACT TRUNCATED AT 250 WORDS)
More Related Videos
08:39Whole-cell Patch-clamp Recordings for Electrophysiological Determination of Ion Selectivity in Channelrhodopsins
Published on: May 22, 2017
05:42Measurement of Ion Concentration in the Unstirred Boundary Layer with Open Patch-Clamp Pipette: Implications in Control of Ion Channels by Fluid Flow
Published on: January 7, 2019
Related Concept Videos
Resting Membrane Potential
The Inside of a Neuron is More Negative
The membrane potential of a cell can be measured by inserting a microelectrode into a cell and comparing the charge to a reference electrode in the extracellular fluid. The...
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Design Example: Frog Muscle Response