Determination of zonisamide by a coated monolithic column
1Department of Chemistry, Xixi campus, Zhejiang University, Hangzhou 310028, China.
Abstract:
In this paper, a monolithic ODS-silica gel column dynamically coated with cetylpyridinium chloride (CPC) was used to demonstrate the high-speed and efficient separation of zonisamide (1,2-benzisoxazole-3-methanesulfonamide, ZNS), its raw material (1,2-benzisoxazole-3-methanecarbonic acid) and intermediate (sodium 1,2-benzisoxazole-3-methanesulfonate) in drugs. Using a 40 mmol/L sodium perchlorate solution (pH 7.0) containing 10% acetonitrile as eluent, the analytes were eluted with a sharp and symmetrical peak within 3.0 min, detected with UV detection at 210 nm. The column demonstrates excellent stability over time, and exhibits unusual selectivity for pharmaceutical analysis. Thus, by this developed method, zonisamide in drug samples can be determined rapidly with high recoveries and good selectivity.
More Related Videos
11:44Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B
Published on: January 19, 2022
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019