Related Experiment Video
Updated: Jul 31, 2026

Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
Differential pulse, square wave and adsorptive stripping voltammetric quantification of tianeptine in tablets
Azza A Gazy1, Hoda Mahgoub, Essam F Khamis
1Faculty of Pharmacy, Department of Pharmaceutical Analytical Chemistry, University of Alexandria, El-Messalah, Alexandria 21521, Egypt. azzgazy@yahoo.com
Abstract:
Differential pulse polarographic (DPP) and square wave polarographic (SWP) techniques were applied at hanging mercury drop electrode (HMDE) for quantitative determination of tianeptine (TIA) in tablets. The adsorptive stripping voltammetric (ASV) behavior of TIA was also studied. TIA gave a sensitive reduction peaks at -1256, -1244 and -1072 mV for DPP, SWP and ASV, respectively (versus Ag/AgCl) in Britton-Robinson buffer (B-R buffer) at pH 11. The solution conditions and instrumental parameters were optimized for the determination of TIA in tablets. Calibration plots and regression data validation, accuracy, precision, limit of detection, limit of quantitation and other aspects of analytical merit are presented.
Related Concept Videos
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Cyclic Voltammetry
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...