Isocratic separation of ginsenosides by high-performance liquid chromatography on a diol column at subambient
Da-Wei Lou1, Yoshihiro Saito, Paweł K Zarzycki
1School of Materials Science, Toyohashi University of Technology, Toyohashi, 441-8580, Japan.
Abstract:
An improved high-performance liquid chromatographic method for separation of a number of ginsenosides has been developed. The influence of temperature (from 0 to 25 degrees C) on the retention and separation of the ginsenosides was studied by applying a binary mobile phase (acetonitrile/water, 82:18 v/v) and a diol column (LiChrospher 100 Diol). The column temperature is one of the more important parameters for the retention and separation of the components investigated. Selected thermodynamic parameters, including changes of enthalpy (deltaH degrees) and entropy (deltaS degrees), were estimated from linear van't Hoff plots, and possible retention mechanisms were discussed. Moreover, the best separation conditions were selected based on optimization criteria including maximum retention time (t(R max)), minimum resolution (R(s min)), and relative resolution product (r). Temperature regions close to 14 degrees C offered the highest selectivity and almost equal distribution of the ginsenosides peaks across the chromatogram. Under such isocratic conditions, excellent separation of chromatographic standards and selected ginseng samples was achieved in less than 16 min.
More Related Videos
10:09A Straightforward Method for Glucosinolate Extraction and Analysis with High-pressure Liquid Chromatography (HPLC)
Published on: March 15, 2017
09:01Extraction and Quantification of Soluble, Radiolabeled Inositol Polyphosphates from Different Plant Species using SAX-HPLC
Published on: June 26, 2020
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
