Related Experiment Video
Updated: Aug 9, 2026

High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis
Published on: September 22, 2017
Simultaneous observation of CO isotopomer absorption by broadband difference-frequency generation using a
Tsutomu Yanagawa1, Osamu Tadanaga, Yoshiki Nishida
1NTT Photonics Laboratories, NTT Corporation, 3-1, Morinosato Wakamiya, Atsugi, Kanagawa 243-0198, Japan. yanagawa@aecl.ntt.co.jp
Abstract:
Rovibration absorption lines both of 12CO and 13CO are observed simultaneously with the output of a 2 microm broadband difference frequency generated in a direct-bonded quasi-phase-matched LiNbO3 waveguide, which is a 50 mm device with a single quasi-phase-matching period that is operated at a constant temperature. The wavelength conversion efficiency and the difference-frequency generation bandwidth reach 100%/W and 100 nm, respectively. The idler output bandwidth in the 2 microm region is obtained by group-velocity matching or phase-mismatch minimization when a 0.94 microm pump laser diode and a 1.55 microm tunable signal source are used.
Related Concept Videos
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
IR Absorption Frequency: Hybridization
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that stretch at a...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.