Related Experiment Video
Updated: Aug 9, 2026

Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
Monolithic poly(p-methylstyrene-co-1,2-bis(p-vinylphenyl)ethane) capillary columns as novel styrene stationary phases
Lukas Trojer1, Said H Lubbad, Clemens P Bisjak
1Institute of Analytical Chemistry and Radiochemistry, Leopold-Franzens University, Innrain 52a, 6020 Innsbruck, Austria.
Abstract:
Novel monolithic capillary supports (200 microm I.D.) were prepared by polymerisation of methylstyrene (MS) and 1,2-bis(p-vinylphenyl)ethane (BVPE) as a crosslinker in the presence of inert diluents (porogens). These polymeric reversed-phases (MS/BVPE) showed excellent mechanical stability and minimised swelling in organic solvents. The chromatographic potential of monolithic MS/BVPE as a stationary phase for micro-high-performance liquid chromatography (mu-HPLC) was investigated by the separation of proteins and peptides applying reversed-phase (RP) and nucleic acids applying ion-pair reversed-phase (IP-RP) conditions. The permeability and chromatographic efficiency of the capillary columns were found to be highly influenced by the total monomer to porogen content as well as by the microporogen nature and its ratio. In the course of these optimisation studies, monoliths covering a broad permeability range were fabricated. The application of volumetric flow rates up to 200 microl/min allowed swift resolution of proteins, while smaller biomolecules were successfully separated at a higher overall porosity. A protein test mixture containing ribonuclease A, cytochrome c, alpha-lactalbumin, beta-lactoglobulin B and ovalbumin was thus baseline separated in 35s, a homologous series of phosphorylated oligothymidylic acids [d(pT)12-18] in less than 2 min.
More Related Videos
09:02Using Polystyrene-block-poly(acrylic acid)-coated Metal Nanoparticles as Monomers for Their Homo- and Co-polymerization
Published on: July 9, 2015
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Principles Of Column Chromatography