Related Experiment Video
Updated: Aug 9, 2026

Use of Capillary Aerosol Generator in Continuous Production of Controlled Aerosol for Non-Clinical Studies
Published on: April 12, 2022
Determination of orthophthalaldehyde in air using 2,4-dinitrophenylhydrazine-impregnated silica cartridge and
Shigehisa Uchiyama1, Erika Matsushima, Hiroshi Tokunaga
1Faculty of Engineering, Chiba University 1-33, Yayoi-Cho, Inage-Ku, Chiba City, Chiba 263-8522, Japan. ucym@tu.chiba-u.ac.jp
Abstract:
A new method is described for the determination of orthophthalaldehyde in air which is used for the disinfection of various instruments (e.g. endoscopes) in hospital. Orthophthalaldehyde in air was collected with a silica gel cartridge impregnated with acidified 2,4-dinitrophenylhydrazine (DNPH-cartridge) and derivatives were analyzed by high-performance liquid chromatography (HPLC). In this study, the derivatization was examined by comparing the process with three phthalaldehyde isomers (ortho-, iso- and tere-). In the case of iso- and tere-phthalaldehyde, derivatives synthesized with excess of aldehyde consisted mainly of mono-derivatives, and derivatives synthesized with excess of DNPH consisted mainly of bis-derivative. In the case of orthophthalaldehyde, derivative consisted of only bis-derivative and mono-derivative was never observed under any conditions. Orthophthalaldehyde was completely retained by the DNPH-cartridge during air sampling, however, the derivatization reaction was incomplete and unreacted orthophthalaldehyde was flushed from the cartridge during the subsequent solvent extraction process. Unreacted orthophthalaldehyde and DNPH reacted again in the extraction solvent solution. Immediately after the solvent extraction, both mono- and bis-DNPhydrazone derivatives of orthophthalaldehyde were present in the solution. However, over time, the mono-derivative decreased and bis-derivative increased until only the bis-derivative was left allowing accurate determination of the orthophthalaldehyde concentration. The transformation of mono-derivative to bis-derivative was faster in polar aprotic solvents such as acetonitrile, dimethyl sulfoxide and ethyl acetate. Transformation was found to occur most quickly in acetonitrile solvent and was completed in 4 h in this case. It was possible to measure orthophthalaldehyde in air as bis-derivative using a DNPH impregnated silica cartridge and HPLC analysis.
More Related Videos
10:42Preparation of N-(2-alkoxyvinyl)sulfonamides from N-tosyl-1,2,3-triazoles and Subsequent Conversion to Substituted Phthalans and Phenethylamines
Published on: January 3, 2018
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Instrumentation