Related Experiment Video
Updated: Aug 9, 2026

The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Chlorine residual efficiency in inactivating bacteria from secondary contamination in Isfahan, 2002
A Tavakoli1, R Yazdani, M R Shahmansouri
1Department of Microbiology, Isfahan University of Medical Sciences, Isfahan, Islamic Republic of Iran. ak_ta_ir@yahoo.com
Abstract:
To investigate the inactivation of potential pathogens, we evaluated survival rates for Escherichia coli, Enterococcus faecalis, Aeromonas hydrophila and Salmonella typhi in samples taken from the Isfahan drinking water system. Chlorine residual, pH, temperature and total organic carbon levels were measured. The organism most sensitive to chlorine was A. hydrophila. It was inactived in < 100 minutes at chlorine levels of 0.11 mg/L to 0.90 mg/L. The other 3 organisms showed higher resistance. E. coli tolerated 0.30 mg/L chlorine for > 1000 minutes while Ent. faecalis and S. typhi survived at total chlorine concentration of 0.50 mg/L for 100 minutes. We concluded that total chlorine levels of less than 0.71 mg/L in water supply systems cannot provide the recommended safety levels.
Related Concept Videos
Microbial Bioremediation of Pesticides
Antimicrobial Effectiveness
Chemical Agents for Microbial Control
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...