Characterization of a mid-infrared hollow waveguide gas cell for the analysis of carbon monoxide and nitric oxide
Related Experiment Video
Updated: Aug 9, 2026

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Bruce T Thompson1, A Inberg, N Croitoru
1Brown & Williamson Tobacco Corp., P.O. Box 1056, Macon, Georgia 31202, USA.
Abstract:
Infrared spectroscopy is commonly applied to the analysis of small gas-phase molecules. One of the limitations of using Fourier transform infrared (FT-IR) spectroscopy for these applications is the time response of long path length gas cells. Hollow waveguides (HW) that transmit in the mid-infrared spectral range have higher optical efficiencies compared to long path length cells due to smaller cell volumes. This study characterizes a silver coated, 2 mm inner diameter HW for the analysis of carbon monoxide (CO) and nitric oxide (NO) and compares the performance to a 3 m gas cell and traditional gas analyzers. The HW was found to have a CO response time less than the NDIR analyzer and approximately one-tenth of the response time on the FT-IR system equipped with a 3 m gas cell. The utility of the increased response time was demonstrated by measuring CO concentrations in sidestream cigarette smoke at the same temporal resolution as an NDIR analyzer. A 10 to 60% increase in sensitivity using various frequencies for both CO and NO was observed using the HW compared to the 3 m multipass gas cell. However, cost savings for gas-sensing applications can be achieved on a per analyte basis by using FT-IR spectroscopy, especially in combination with a HW gas-sensing module, which is significantly less expensive than a multipass gas cell.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to the...