Dose distribution around a needle-like anode X-ray tube: dye-film vs. planar thermoluminescent detectors
M Budzanowski1, P Olko, B Marczewska
1Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN), ul. Radzikowskiego 152, PL-31-342 Kraków, Poland. maciej.budzanowski@ifj.edu.pl
Abstract:
The dosimetry around the X-ray tube with a needle-like anode (NAXT), developed at the Institute of Nuclear Studies, for interstitial brachytherapy has been performed using (1) dye films (Gafchromic XR-T), (2) large-area thermoluminescent (TL) detectors--prepared either by gluing TL powder onto thin Al foil (so-called planar detectors with spatial resolution of 0.1 mm) and (3) miniature (2 mm diameter and 0.5 mm thick) TL detectors. The measurements were performed in following geometries. (1) Needle inside a PMMA cylinder--the planar TL detector mounted on the surface of the cylinder. (2) Needle inside a thick block of PMMA and TL detector mounted vertically 7 mm from needle axis. TL detectors were read with the planar (2D) thermoluminescence reader, developed at IFJ, with a sensitive CCD (charge couple device) camera. Gafchromic films were evaluated with a system based on Agfa Arcus 1200 scanner and calibrated with X rays (35 kV) filtered with 0.03 mm Mo and with Co-60 photons. The intensity distribution of TL light on the planar detector was calibrated in terms of absorbed dose to water, using (137)Cs gamma-rays. TL planar detectors seem to be a promising tool for 2D dosimetry of miniature X-ray sources. Obtained results for TLDs and Gafchromic films seem to be comparable but differences have been found. Both methods are useful for measurements of dose distribution around the NAXT X-rays source.
More Related Videos
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Determination of Crystal Structures
X-ray Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Gas Chromatography: Types of Detectors-II
Biological Effects of Radiation