Related Experiment Video
Updated: Aug 9, 2026

Design of a Biocompatible Drug-Eluting Tracheal Stent in Mice with Laryngotracheal Stenosis
Published on: January 21, 2020
Treatment of tracheobronchial obstruction with a polytetrafluoroethylene-covered retrievable expandable nitinol stent
Ji Hoon Shin1, Ho-Young Song, Gi Young Ko
1Department of Radiology and the Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 388-1, Pungnap-2dong, Songpa-gu, Seoul, 138-736, Korea.
Purpose:
To evaluate the clinical effectiveness of polytetrafluoroethylene (PTFE)-covered retrievable expandable nitinol stents in tracheobronchial strictures.
Materials And Methods:
With fluoroscopic guidance, PTFE-covered retrievable expandable nitinol stents were placed in 15 symptomatic patients with benign (n = 6) or malignant (n = 9) tracheobronchial strictures. Complications and improvement in respiratory status were evaluated. Stents were removed electively 6 months after placement in benign strictures or if complications occurred. Membrane degradation or separation from the wire mesh was evaluated in removed stents.
Results:
A total of 17 stents were successfully placed and were well tolerated in all patients. Sputum retention, stent migration, and tissue hyperplasia occurred in 23.5% (n = 4), 17.6% (n = 3), and 17.6% (n = 3) of stents, respectively. A total of 11 stents were successfully removed electively 6 months after placement (n = 4) or when complications occurred (n = 7). All 11 such stents were removed without difficulty with use of standard techniques, antecedent balloon dilation being necessary in two cases as a result of tissue hyperplasia. No removed stent showed signs of membrane degradation, and two removed stents showed signs of membrane separation from the mesh.
Conclusions:
PTFE-covered retrievable expandable nitinol stents were effective in the treatment of tracheobronchial strictures. Stent removal was easy with use of standard techniques, and no removed stent showed evidence of membrane degradation.
Related Concept Videos
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of the...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...