Related Experiment Video
Updated: Aug 9, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Development and application of porous membrane-protected carbon nanotube micro-solid-phase extraction combined with
Chanbasha Basheer1, Anass Ali Alnedhary, B S Madhava Rao
1Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore.
Abstract:
A novel, multiwalled carbon nanotube (MWCNT)-supported micro-solid-phase extraction (mu-SPE) procedure has been developed. A 6-mg sample of MWCNTs was packed inside a (2 cm x 1.5 cm) sheet of porous polypropylene membrane whose edges were heat-sealed to secure the contents. The mu-SPE device, which was wetted with dichloromethane, was then placed in a stirred sewage sludge sample solution to extract organophosporous pesticides, used here as model compounds. Tumbling of the extraction device within the sample solution facilitated extraction, and the porous membrane acted as a filter to exclude the extraction of extraneous materials. After extraction, analytes were desorbed in hexane and analyzed using gas chromatography/mass spectrometry. Since the porous membrane afforded protection of the MWCNTs, no further cleanup of the extract was required. The pi-pi electrostatic interaction with the analytes and the large surface area of MWCNTs facilitated the adsorption of analytes, with good selectivity and reproducibility. Under the optimized extraction conditions, the method showed good linearity in the range of 0.1-50 mug/L, repeatability of the extractions (RSD 2-8%, n = 4), and low limits of detection (1-7 pg/g). No analyte carryover effect was observed, and each mu-SPE device could be used for up to 30 extractions. Comparison was made with hollow fiber protected solid-phase microextraction and headspace solid-phase microextraction; mu-SPE was demonstrated to be a fast, accurate, and cost-effective pretreatment method for sewage sludge samples.
More Related Videos
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...