Related Experiment Video
Updated: Aug 9, 2026

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
The optimal method for recording prosthetic heart valve sounds in clinical situations
Yasuyuki Bito1, Yoshiharu Soeta, Seiji Nakagawa
1Department of Cardiovascular Surgery, Osaka City University, Graduate School of Medicine, 1-4-3, Asahimachi, Abeno-ku, Osaka 545-8585, Japan. ybito@med.osaka-cu.ac.jp
Background:
Valve sounds are thought to be useful in evaluating the functioning of prosthetic heart valves. In previous reports, two recording instruments have mainly been used, a condenser microphone (instrument A) and an accelerometer (instrument B), respectively. This study aimed to investigate the applicability of these conventional devices in recording mechanical heart valve sounds in daily clinical situations. In addition, two other instruments, namely, a stethoscope including a small microphone in its tube (instrument C) and an electrostethoscope (instrument D), were proposed and examined.
Methods:
Mechanical valve sounds were recorded from postoperative patients using each-device and the signal to noise ratio (SNR) of each was calculated. Frequency characteristics of the two newly proposed instruments were also investigated by recording a sweep signal in an anechoic chamber.
Results:
The SNR values of the new instruments were significantly superior to those of conventional ones (A, sound signals were not defined from noises; B, 0.97 +/- 0.59 dB; C, 11.5 +/- 4.7 dB; and D, 9.4 +/- 3.5 dB, respectively p<0.05). The frequency characteristics of the two newly proposed instruments were also shown to be acceptable (under 10 kHz), though resonance frequency peaks were observed.
Conclusions:
Two newly proposed instruments can record mechanical heart valve sounds more noiselessly and with more ease than previous ones, and their frequency characteristics are acceptable.
Related Concept Videos
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...

