Related Experiment Video
Updated: Aug 9, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Determination of benzodiazepines in human urine using solid-phase extraction and high-performance liquid
S Hegstad1, E L Øiestad, U Johansen
1Norwegian Institute of Public Health, Division of Forensic Toxicology and Drug Abuse, P.O. Box 4404 Nydalen, NO-0403 Oslo, Norway. solfrid.hegstad@fhi.no
Abstract:
A liquid chromatography-tandem mass spectrometry (LC-MS-MS) method has been developed and validated for the determination of benzodiazepines, on the market in Norway, and/or their metabolites in human urine. The following compounds were included: 7-aminonitrazepam, 7-aminoclonazepam, 7-aminoflunitrazepam, alprazolam, alpha-hydroxyalprazolam, oxazepam, 3-OH-diazepam, and n-desmethyldiazepam. The method includes hydrolysis of urine samples (0.5 mL) with beta-glucuronidase at 60 degrees C for 2 h before solid-phase extraction with a polymer-based mixed-mode column. The analytes were quantified in multiple reaction monitoring mode using two transitions. Deuterated analogues were used as internal standards for all analytes except 7-aminonitrazepam and alpha-hydroxyalprazolam, which were quantified using 7-aminoclonazepam-d(4) and alprazolam-d(5), respectively. The concentration range was 0.1-8.0 microM for 7-aminonitrazepam, 7-aminoclonazepam, 7-aminoflunitrazepam, alprazolam, and alpha-hydroxyalprazolam and 0.5-40 microM for the other compounds. The average recovery for the different analytes ranged from 56% to 83%. The between-day precision of the method was in the range of 3-12%. The limits of quantification were found to be between 0.002 and 0.01 microM for the different compounds. Comparison with other analytical methods was performed for method validation, using approximately 500 samples provided by the routine laboratory at the Norwegian Institute of Public Health. The LC-MS-MS method has proven to be robust and specific for the determination of benzodiazepines in urine. It has been routinely used for approximately 1800 samples in the past 7 months.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...