Related Experiment Video
Updated: Aug 9, 2026

Automation of Mode Locking in a Nonlinear Polarization Rotation Fiber Laser through Output Polarization Measurements
Published on: February 28, 2016
Analysis of nonlinear phase noise in single-channel return-to-zero differential phase-shift keying transmission
Fan Zhang1, Christian-A Bunge, Klaus Petermann
1Fachgebiet Hochfrequenztechnik, Technische Universität Berlin, D-10587 Berlin, Germany. fzhang99cn@yahoo.com
Abstract:
Self-phase modulation and intrachannel cross-phase-modulation- (IXPM) induced nonlinear phase noise is investigated by the variational method. IXPM can cause a considerable increase of phase noise. We show, however, that IXPM leads to a partial correlation between the phase noises of adjacent pulses, which tends to reduce the influence of nonlinear phase noise in return-to-zero differential phase-shift keying transmission. In highly dispersive transmission systems, intrachannel four-wave mixing-induced differential phase fluctuations are typically larger than differential nonlinear phase noise. The analysis is validated by Monte Carlo simulation.
Related Concept Videos
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Gain
Gain:
Suppose Vin is the input and Vout is the output signal to a circuit.
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear.
Transmission-Line Differential Equations
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured from the...
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...