Related Experiment Video
Updated: Aug 9, 2026

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator
Published on: January 28, 2019
Phase-shifting interferometry in the presence of nonlinear phase steps, harmonics, and noise
Rajesh Langoju1, Abhijit Patil, Pramod Rastogi
1Applied Computing and Mechanics Laboratory, Ecole Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland.
Abstract:
A phase-shifting piezo device commonly employed in phase-shifting interferometry exhibits a nonlinear response to applied voltage. Hence, a method for estimation of phase distribution in the presence of nonlinear phase steps is presented. The proposed method compensates for the harmonics present in the intensity fringe, allows the use of arbitrary phase-step values between 0 and tau rad, and does not impose constraints on the selection of particular phase-step values for minimizing nonlinearity and compensating for the harmonics. The comparison of the proposed method with other well-known benchmarking algorithms shows that our method is highly efficient and also works well in the presence of noise.
Related Concept Videos
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Interference and Diffraction
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Reconstruction of Signal using Interpolation

