Integrated Compensatory Responses in a Human Model of Hemorrhage
Published on: November 20, 2016
Hemodynamic profile, compensation deficit, and ambulatory blood pressure
Cristina Ottaviani1, David Shapiro, Iris B Goldstein
1Department of Psychology, University of Bologna, Bologna, Italy.
Abstract:
This study hypothesized that physiologically grounded patterns of hemodynamic profile and compensation deficit would be superior to traditional blood pressure reactivity in the prediction of daily-life blood pressure. Impedance cardiography-derived measures and beat-to-beat blood pressure were monitored continuously in 45 subjects during baseline and four tasks. Ambulatory blood pressure measures were obtained combining data from one work day and one off day. The mediating effects of gender and family history of hypertension were considered. Only gender was significantly associated with hemodynamic profile. Regression analysis indicated that typical reactivity measures failed to predict everyday life blood pressure. After controlling for gender and baseline blood pressure, hemodynamic patterns during specific tasks proved to be strong predictors, overcoming limitations of previous reactivity models in predicting real-life blood pressure.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: