Computed tomography versus magnetic resonance imaging of endoleaks after EVAR
M J van der Laan1, L W Bartels, M A Viergever
1Department of Vascular Surgery, University Medical Center, Utrecht, The Netherlands. aachi4048@zhh.nl
Aim:
The aim of study was to compare the sensitivity of MRI and CTA for endoleak detection and classification after EVAR.
Patients & Methods:
Twenty-eight patients, between 2 days and 65 months after EVAR, were evaluated with both CT and MRI. Twenty-five patients had an Ancure graft and the other three had an Excluder. The MRI protocol for endoleak evaluation included: a T1-weighted spin echo, a high-resolution 3D CE-MRA, and a post-contrast T1-weighted spin echo. In total 40 ml Gadolinium was administered. The CT protocol consisted of a blank survey followed by a spiral CT angiography (CTA) using 140 ml of Ultravist. An experienced, blinded observer evaluated all CTs and MRIs.
Results:
Using MRI and MRA techniques significantly more endoleaks (23/35) were detected than with CTA (11/35) (p=0.01, Chi-Square). CT could not determine the type of endoleak in 3 of the 11 endoleaks detected and was uncertain in one. MRI was uncertain about the type in 14 of the 23 endoleaks detected. All endoleaks visible on CT were visible by MRI as well.
Conclusions:
MRI techniques are more sensitive for the detection of endoleak after endovascular AAA repair than CT.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...