Related Experiment Video
Updated: Aug 9, 2026

Quantitative Fundus Autofluorescence for the Evaluation of Retinal Diseases
Published on: March 11, 2016
Correlation between optical coherence tomography and autofluorescence in acute posterior multifocal placoid pigment
Ahmed A R Souka1, Jost Hillenkamp, Felix Gora
1Ophthalmology Department, University of Regensburg, Regensburg, Germany.
Purpose:
To report a case of bilateral acute posterior multifocal placoid pigment epitheliopathy (APMPPE) evaluated by optical coherence tomography (OCT), fundus autofluorescence (AF) and microperimetry, both in the acute phase and after resolution of symptoms.
Methods:
Complete ophthalmological evaluation, including fluorescein angiography, OCT, AF, and microperimetry upon presentation and 1 month later, after lesions have subsided. An attempt to correlate the findings on presentation and changes after resolution is performed using the results of these new investigational techniques.
Results:
APMPPE showed hyperreflectance in OCT at the level of the outer retinal layers, without increase in retinal thickness. AF revealed early decreased fluorescence due to a masking effect, and later reveals increased fluorescence after resolution of OCT findings. Function is disturbed at the lesion sites, as shown by microperimetry, and later returns to near normal values on microperimetry.
Conclusion:
APMPPE shows outer retinal layers changes on OCT, which resolve totally after subsidence of the acute phase. AF shows areas of increased fluorescence after resolution, with near normal return of function on microperimetry.