Related Experiment Video
Updated: Aug 9, 2026

Precision Implementation of Minimal Erythema Dose (MED) Testing to Assess Individual Variation in Human Inflammatory Response
Published on: October 3, 2019
A new methodology for the assessment of hand protection from ultraviolet exposure
M Khazova1, J B O'Hagan, K J-L Grainger
1HPA-CRCE, Chilton, Didcot OX11 0RQ, UK. marina.khazova@hpa-rp.org.uk
Abstract:
A number of industrial applications and public services involve occupational exposure to ultraviolet radiation (UVR) from a variety of lamps and lasers. The aim of this study was to develop a methodology for the assessment of the UV protection level for disposable gloves. Glove UV protection factor is defined as a time-scale increase in exposure permitted for the hand protected by a glove with respect to an unprotected hand. Our study showed that for all tested gloves a change in UVR attenuation with stretching is characteristic for the type of glove material and can be included as a scaling factor in the definition of UVR protection. Glove material has a bigger effect on UVR protection level than variations in the glove thickness or its colour. Examples of assessment of the 'worst case scenario' are compared with the protection level against a number of sources, together with the guidance on a simplified evaluation protocol. An application-specific assessment, illustrated for 'SmartWater' forensic examinations and biological trans-illuminators, demonstrates that some gloves provide inadequate protection against occupational UV exposure.
Related Concept Videos
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Hand hygiene
Hand washing...