Related Experiment Video
Updated: Aug 8, 2026

Taking Advantage of Reduced Droplet-surface Interaction to Optimize Transport of Bioanalytes in Digital Microfluidics
Published on: November 10, 2014
Rotating sample system: an equivalent of a rotating electrode for microliter samples
1Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106, USA.
Abstract:
Voltammetric experiments in sample droplets of 20 microL volume were carried out with gold ring electrodes microfabricated on Pyrex substrates. The droplet studied was centered and kept in place by a hydrophobic ring deposited on the substrate around the ring electrode, which also ensured that each sample assume a semispherical shape. A small hole in the center of the substrate filled with an agar gel membrane served as a junction. A mild jet of humidified nitrogen gas directed tangentially at the droplet caused it to rotate at a high rate. Cyclic voltammetry and constant-potential electrolysis of potassium ferricyanide were used to characterize this rotating sample system and to calculate diffusion layer thickness. The results clearly demonstrate that rotating of a semispherical microsample placed above a stationary ring electrode with a mild gas jet can be as effective as a rotating electrode system. As a practical example, voltammetric stripping analysis of 20-120 pmol mercuric nitrate samples was performed with a calibration of good linearity (r2 = 0.988) and a time constant for exhaustive electrolysis of approximately 2 min.

