Abstract:
We investigated the electrical signatures of iron corrosion and mineral precipitation in angle cores from an Fe(0) barrier installation in operation for eight years. The real and imaginary parts of the complex electrical conductivity measured between 0.1 and 1000 Hz were 2-10 times higher (varying between cores) in the reacted zone at the upgradient edge of the barrier relative to less altered locations inside the barrier. Scanning electron microscopy identified iron surface alteration with the thickest corrosion rinds closest to the upgradient soil/iron interface. Surface area of iron minerals was also greatest at the upgradient interface, gradually decreasing into the cores. X-ray diffractometry identified precipitation of iron oxide/hydroxide, carbonate minerals, iron sulfide, as well as green rusts, with mineral complexity decreasing away from the interface. The electrical measurements correlate very well with the solid-phase analyses, and they verify that electrical methods could be used to assess or monitor iron corrosion and mineral precipitation occurring in Fe(0) barriers.
Related Concept Videos
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Electrical Conductivity
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
Corrosion
Magnetic Field Due To A Thin Straight Wire
Resistivity
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...