Gel permeation chromatography of dextrans in parenteral solutions: calibration procedure development and method
S Karmarkar1, R Garber, J Kluza
1Baxter Healthcare, Technology Park, Route 120 and Wilson Road, Round Lake, IL 60073, United States. shreekant_karmarkar@baxter.com
Abstract:
We describe development and validation of a gel permeation chromatographic (GPC) method for dextrans in parenteral solutions. The GPC method was adopted from USP monographs on Dextran 40 and Dextran 70 raw materials. The method was optimized with a mobile phase flow rate of 1 mL/min and column temperature of 40 degrees C, to sharpen dextran and dextrose peaks. An easy-to-use, curve-fitting program capable of non-linear regression was developed in-house, using Microsoft Excel and its Solver add-in to successfully meet the GPC calibration requirements for dextrans and dextrose, i.e., the experimental molecular weights within 100+/-5% of the known molecular weights for dextrans and molecular weight of dextrose within 180+/-2 Da. The GPC method was validated in terms of its stability indicating nature, robustness (column temperature of 40+/-3 degrees C), accuracy (lack of effects of pH and concentration of dextrans or matrix components), and precision (repeatability and intermediate). Molecular weight distribution of dextrans were unchanged when the dextran containing test solutions were subjected to forced degradation using heat, light (daylight and UV light), extreme alkaline conditions or oxidative conditions. The method was capable of detecting changes in molecular weight distribution caused by degradation under extreme acidic conditions and heat, thereby confirming the stability indicating nature of the method. The concentration of Dextran 40 and Dextran 70 (75-125% of the nominal assay concentration), matrix components (108-111% of their nominal concentrations), and solution pH (pH 3-7 for Dextran 40 solutions and pH 4-7 for Dextran 70 solutions) did not affect the measured molecular weight distribution of Dextran 40 or Dextran 70. The method was precise with %R.S.D. of less than 1% for M (W) values of Dextran 40 or Dextran 70.
More Related Videos
07:41High-Throughput Bioprinting Method for Modeling Vascular Permeability in Standard Six-well Plates with Size and Pattern Flexibility
Published on: August 16, 2024
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Dialysis
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Peritoneal Dialysis I: Introduction and Procedure
Drug Dissolution: Requirements and Profile Comparison