Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Validation of a generalized transfer function to noninvasively derive central blood pressure during exercise
James E Sharman1, Richard Lim, Ahmad M Qasem
1Department of Medicine, School of Human Movement Studies, University of Queensland, Princess Alexandra Hospital, Queensland, Australia. jsharman@soms.uq.edu.au
Abstract:
Exercise brachial blood pressure (BP) predicts mortality, but because of wave reflection, central (ascending aortic) pressure differs from brachial pressure. Exercise central BP may be clinically important, and a noninvasive means to derive it would be useful. The purpose of this study was to test the validity of a noninvasive technique to derive exercise central BP. Ascending aortic pressure waveforms were recorded using a micromanometer-tipped 6F Millar catheter in 30 patients (56+/-9 years; 21 men) undergoing diagnostic coronary angiography. Simultaneous recordings of the derived central pressure waveform were acquired using servocontrolled radial tonometry at rest and during supine cycling. Pulse wave analysis of the direct and derived pressure signals was performed offline (SphygmoCor 7.01). From rest to exercise, mean arterial pressure and heart rate were increased by 20+/-10 mm Hg and 15+/-7 bpm, respectively, and central systolic BP ranged from 77 to 229 mm Hg. There was good agreement and high correlation between invasive and noninvasive techniques with a mean difference (+/-SD) for central systolic BP of -1.3+/-3.2 mm Hg at rest and -4.7+/-3.3 mm Hg at peak exercise (for both r=0.995; P<0.001). Conversely, systolic BP was significantly higher peripherally than centrally at rest (155+/-33 versus 138+/-32 mm Hg; mean difference, -16.3+/-9.4 mm Hg) and during exercise (180+/-34 versus 164+/-33 mm Hg; mean difference, -15.5+/-10.4 mm Hg; for both P<0.001). True myocardial afterload is not reliably estimated by peripheral systolic BP. Radial tonometry and pulse wave analysis is an accurate technique for the noninvasive determination of central BP at rest and during exercise.
More Related Videos
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.