Related Experiment Video
Updated: Aug 8, 2026

Sensitivity Enhancement of Soft Capacitive Pressure Sensors Using a Solvent Evaporation-Based Porosity Control Technique
Published on: March 24, 2023
Comparison of capacitive versus resistive joint contact stress sensors
L Martinelli1, C Hurschler, D Rosenbaum
1Motion Analysis Laboratory, University Hospital Muenster, Muenster, Germany.
Abstract:
Cartilage contact stress elevations might be associated with pain or other symptoms after malunited, incongruous intraarticular fractures. Studies identifying fractures with patterns of elevated contact stresses would help to ensure more appropriate choices of treatment. However, appropriate instrumentation for such studies is crucial. We tested two such systems, one capacitive and one resistive, under identical loading conditions presumed to occur in the ankle. We used a materials testing machine and customized-loading fixtures to measure force detection error, contact area error, repeatability, homogeneity, creep, and one-axis and two-axis bending artifacts. The loading regimen caused pressures up to 2.5 MPa. An error in force detection between -3% and +5% was observed with the capacitive sensor whereas an error between -12% and +20% was observed with the resistive sensor. Repeatability and homogeneity were greater for the capacitive sensor. Errors in contact area measurement were less than 2% for the resistive sensor and less than 6% for the capacitive sensor. The resistive sensor could not conform to spherical surfaces without crinkling. Creep artifact was observed with both sensors. We concluded that the capacitive sensor had superior performance even though its thickness and high compliance may be disadvantageous in intraarticular measurements. The resistive sensor is required for use where higher pressures are expected despite its inferior accuracy.
Related Concept Videos
Design Example: Resistive Touchscreen
When a user touches the screen, the two layers make contact at a specific point known as the touchpoint. This contact reduces the resistance between...
Design Example: Strain Gauge Bridge or Wheatstone Bridge
Capacitors and Capacitance
When the conductors are two identical parallel plates, it is called a parallel plate capacitor. When battery terminals are...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Equivalent Resistance
Capacitors in Series and Parallel
Suppose the capacitors are connected one after the other such that the negative terminal of the first connects to the positive terminal of the...