Introduction:
Diffusion-weighted imaging (DWI) is usually performed before injection of intravenous paramagnetic contrast medium. Occasionally, it may be necessary to perform or to repeat DWI after such administration. Our purpose was to evaluate the effect of intravenous gadodiamide (Gd [DTPA-BMA]) on DWI.
Methods:
DWI was performed on 88 brain lesions immediately before, immediately after, and 5-10 min following the end of 0.1 mmol/kg Gd [DTPA-BMA] administration. Signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) of the lesions, and the SNRs of normal brain tissue were calculated on b=0 s/mm(2) and b=1,000 s/mm(2) DW images. Apparent diffusion coefficient (ADC) values of the lesions were measured on ADC maps. A paired t-test was used to determine the significance of differences between the values before and after administration of contrast medium.
Results:
The lesions consisted of 23 intraaxial and 11 extraaxial masses, 19 ischemic strokes, 15 intracranial hemorrhages and 20 demyelinating lesions. Images before and after contrast administration were not significantly different regarding SNRs and CNRs on DWI. This statement was also true for strongly enhanced lesions. However, ADC values significantly decreased after contrast medium injection on early post-contrast DWI in normal brain tissue (1%, P<0.049) and (3%, P<0.008) in lesions. By contrast, on late images, ADC values were normalized.
Conclusion:
Contrast medium injection had significant and time-dependent effects on ADC values. Therefore, only pre-contrast and late DW images should be used in quantitative ADC studies.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Imaging Studies for Cardiovascular System V: CT