Related Experiment Video
Updated: Aug 6, 2026

Visual Evoked Potential Recordings in Mice Using a Dry Non-invasive Multi-channel Scalp EEG Sensor
Published on: January 12, 2018
A simple model for the generation of the vestibular evoked myogenic potential (VEMP)
Hero P Wit1, Charlotte M Kingma
1Department of Otorhinolaryngology, University Medical Center Groningen, P.O. Box 30.001, 9700 RB Groningen, The Netherlands. h.p.wit@med.umcg.nl
Objective:
To describe the mechanism by which the vestibular evoked myogenic potential is generated.
Methods:
Vestibular evoked myogenic potential generation is modeled by adding a large number of muscle motor unit action potentials. These action potentials occur randomly in time along a 100 ms long time axis. But because between approximately 15 and 20 ms after a loud short sound stimulus (almost) no action potentials are generated during VEMP measurements in human subjects, no action potentials are present in the model during this time.
Results:
The evoked potential is the result of the lack of amplitude cancellation in the averaged surface electromyogram at the edges of this 5 ms long time interval.
Conclusions:
The relatively simple model describes generation and some properties of the vestibular evoked myogenic potential very well.
Significance:
It is shown that, in contrast with other evoked potentials (BAEPs, VERs), the vestibular evoked myogenic potential is the result of an interruption of activity and not that of summed synchronized neural action potentials.
Related Concept Videos
The Vestibular System
Equilibrium and Balance