Related Experiment Video
Updated: Aug 8, 2026

In situ Grazing Incidence Small Angle X-ray Scattering on Roll-To-Roll Coating of Organic Solar Cells with Laboratory X-ray Instrumentation
Published on: March 2, 2021
A semianalytic model to extract differential linear scattering coefficients of breast tissue from energy dispersive
Robert J LeClair1, Michel M Boileau, Yinkun Wang
1Department of Physics and Astronomy, Laurentian University, 935 Ramsey Lake Road, Sudbury, Ontario, P3E 2C6, Canada. rleclair@laurentian.ca
Abstract:
The goal of this work is to develop a technique to measure the x-ray diffraction signals of breast biopsy specimens. A biomedical x-ray diffraction technology capable of measuring such signals may prove to be of diagnostic use to the medical field. Energy dispersive x-ray diffraction measurements coupled with a semianalytical model were used to extract the differential linear scattering coefficients [mus(x)] of breast tissues on absolute scales. The coefficients describe the probabilities of scatter events occuring per unit length of tissue per unit solid angle of detection. They are a function of the momentum transfer argument, x=sin(theta/2)/X, where theta=scatter angle and lambda=incident wavelength. The technique was validated by using a 3 mm diameter 50 kV polychromatic x-ray beam incident on a 5 mm diameter 5 mm thick sample of water. Water was used because good x-ray diffraction data are available in the literature. The scatter profiles from 6 degrees to 15 degrees in increments of 1 degrees were measured with a 3 mm x 3 mm x 2 mm thick cadmium zinc telluride detector. A 2 mm diameter Pb aperture was placed on top of the detector. The target to detector distance was 29 cm and the duration of each measurement was 10 min. Ensemble averages of the results compare well with the gold standard data of A. H. Narten ["X-ray diffraction data on liquid water in the temperature range 4 degrees C-200 degrees C," ORNL Report No. 4578 (1970)]. An average 7.68% difference for which most of the discrepancies can be attributed to the background noise at low angles was obtained. The preliminary measurements of breast tissue are also encouraging.
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Determination of Crystal Structures

