Characterization of Biological Absorption Spectra Spanning the Visible to the Short-Wave Infrared
Published on: January 10, 2025
Insight into the binding of divalent cations to Sepia eumelanin from IR absorption spectroscopy
1Department of Chemistry, Duke University, Durham, NC, USA.
Abstract:
IR absorption spectroscopy is used to examine the binding of the divalent cations Mg(II), Ca(II), Zn(II) and Cu(II) to melanin granules isolated from the ink sacs of Sepia officinalis. The functional groups of the melanin granules interacting with the bound metal ions are deduced by examining the effect of metal concentration on transition frequencies associated with the COOH, NH and OH moieties of the pigment. The coordinating groups vary with metal ion and with concentration. For the experimental conditions used (initial solution pH of 4, ionic strength of 100 mM and a melanin concentration of 1 mg mL(-1)) Mg(II), Ca(II) and Zn(II) bind to carboxylate groups and Cu(II) binds predominantly to phenolic (catechol) groups However, at a concentration of 10 mM Cu(II) also shows evidence of binding to carboxylate and amine groups, reflecting a secondary binding site that becomes populated as the catechol sites are depleted.
More Related Videos
08:54Vibrational Spectra of a N719-Chromophore/Titania Interface from Empirical-Potential Molecular-Dynamics Simulation, Solvated by a Room Temperature Ionic Liquid
Published on: January 25, 2020
11:38Quantifying the Binding Interactions Between Cu(II) and Peptide Residues in the Presence and Absence of Chromophores
Published on: April 5, 2022
Related Concept Videos
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent of conjugation in the...
UV–Vis Spectrum
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar absorptivity (ε) or log ε on the y-axis (ordinate)...
UV–Vis Spectroscopy: Woodward–Fieser Rules
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human eye.
UV–Vis Spectrometers
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview