Related Experiment Video
Updated: Aug 8, 2026

Human In Vitro Suppression as Screening Tool for the Recognition of an Early State of Immune Imbalance
Published on: July 22, 2011
Redox-sensitive contrast agents for MRI based on reversible binding of thiols to serum albumin
Natarajan Raghunand1, Bhumasamudram Jagadish, Theodore P Trouard
1Department of Radiology, University of Arizona, Tucson, 85724, USA. raghunan@email.arizona.edu
Abstract:
DOTA-based complexes of gadolinium (Gd) bearing a thiol moiety on a propyl or hexyl arm were synthesized. It was hypothesized that these complexes would form reversible covalent linkages with human serum albumin (HSA), which contains a reactive thiol at cysteine-34. The binding constant of the hexyl complex to HSA was measured to be 64 mM(-1) and decreased to 17, 6.1, and 3.6 mM(-1) in the presence of 0.5, 1, and 2 mM homocysteine, respectively. The binding constant of the propyl complex to HSA was significantly lower (5.0 mM(-1)) and decreased to 2.0, 1.5, and 0.87 mM(-1) in the presence of 0.5, 1, and 2 mM homocysteine, respectively. The longitudinal water-proton relaxivities of the hexyl and propyl complexes at 37 degrees C and 4.7 T were 2.3 and 2.9 mM(-1) s(-1), respectively, in saline. The relaxivities of the HSA-bound forms of the hexyl and propyl complexes were calculated to be 5.3 and 4.5 mM(-1) s(-1), respectively. The in vivo pharmacokinetics of both thiol complexes were altered by a chase of homocysteine but not saline, while the washout of GdDTPA was unaffected by either chase. Such redox-sensitive reversible binding of Gd complexes to plasma albumin can be exploited for imaging tissue redox and the blood-pool by MRI.
More Related Videos
08:47Synthesis and Bioconjugation of Thiol-Reactive Reagents for the Creation of Site-Selectively Modified Immunoconjugates
Published on: March 6, 2019
13:21Preparation, Purification, and Characterization of Lanthanide Complexes for Use as Contrast Agents for Magnetic Resonance Imaging
Published on: July 21, 2011
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Redox Titration: Other Oxidizing and Reducing Agents
Redox Titration: Overview
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...