Related Experiment Video
Updated: Aug 8, 2026

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
The dex/CRH test--is it better than the DST?
Stuart Watson1, Peter Gallagher, Margaret S Smith
1School of Neurology, Neurobiology and Psychiatry, The Stanley Research Centre, University of Newcastle upon Tyne, Leazes Wing (Psychiatry), Royal Victoria Infirmary, Newcastle upon Tyne NE1 4LP, UK. stuart.watson@ncl.ac.uk
Abstract:
The dexamethasone suppression test (DST), frequently abnormal in mood disorder patients, is considered to measure glucocorticoid receptor-mediated negative feedback. We examined the hypothesis that the, apparently more sensitive, dexamethasone/corticotrophin-releasing-hormone (dex/CRH) test unveils subtle hypothalamic-pituitary-adrenal axis disturbance not detected by the DST in 82 patients with mood disorders and 28 controls. There was a close correlation between the cortisol responses on the two tests (r(s)=0.73, p<0.0005). However, ROC analysis revealed that the dex/CRH test had better diagnostic performance than the DST (p=0.031). The sensitivity of delta cortisol (from the dex/CRH) was 61.9% and the specificity 71.4%. The sensitivity of 1500 h cortisol (the DST) was 66.6% and the specificity was 47.6%. This suggests that the two tests measure common pathology but that the dex/CRH test has better diagnostic utility.
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...

