Related Experiment Video
Updated: Aug 8, 2026

X-ray Diffraction of Intact Murine Skeletal Muscle as a Tool for Studying the Structural Basis of Muscle Disease
Published on: July 18, 2019
Small-Angle X-ray Diffraction of Muscle Using Undulator Radiation from the Tristan Main Ring at KEK
Abstract:
Time-resolved X-ray diffraction of muscle has demanded ever-increasing flux into small sample volumes with low beam divergence. Results are reported of static and time-resolved small-angle X-ray diffraction studies on muscle fibers using a hard X-ray undulator installed in the Tristan main ring at KEK, Tsukuba, Japan, as an innovative source of synchrotron radiation more intense and better collimated than that available with the Photon Factory bending-magnet beamline. Static studies used the low divergence of the source to obtain detailed high-quality diffraction patterns of stable muscle states. The diffraction patterns from live skeletal muscles showed the numerous (over 100) meridional reflections. The well collimated beam from the undulator made it possible to clearly resolve, with an angular resolution of ca 700 nm, the closely spaced diffraction peaks arising from the two halves of the thick filaments centred on the M lines in a sarcomere, in addition, the diffraction peaks from the thin filaments on opposite sides of the Z bands could be resolved with an angular resolution of ca 1000 nm. The detailed structure of the meridional pattern defines the nature of the molecular packing in the thick and thin filaments. Time-resolved experiments using a focusing mirror aimed to prove cross-bridge states in striated muscle fibers by collecting X-ray diffraction data at a 0.185 ms time resolution from sinusoidally oscillating chemically skinned rabbit muscle fibers during active contraction and in rigor. When sinusoidal length changes at 500 Hz with a peak-to-peak amplitude of 0.6% of the muscle length were applied to a small fiber bundle, the tension showed a simple elastic response during the length oscillation. In the active muscle the intensity of the 14.5 nm myosin-based meridional reflection changed out of phase with the tension change during the oscillating length change. In contrast, in the rigor muscle it occurred in phase with the tension change. The high time-resolved experiments provide an insight into the coupling between conformational changes and force generation of the actomyosin cross-bridges. These studies provide a preview of the expected gains for muscle studies from the more widespread use of undulator radiation at third-generation synchrotron sources.
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Determination of Crystal Structures

