[Interactions between solvents and noise: state of the art]

A Volpin1, B Saia

  • 1Dipartimento Medicina Ambientale e Sanità Pubblica - Università degli Studi di Padova, Italy.

Related Concept Videos

Entropy and Solvation02:05

Entropy and Solvation

The process of surrounding a solute with solvent is called solvation. It involves evenly distributing the solute within the solvent. The rule of thumb for determining a solvent for a given compound is that like dissolves like. A good solvent has molecular characteristics similar to those of the compound to be dissolved. For example, polar solutions dissolve polar solutes, and apolar solvents dissolve apolar solutes. A polar solvent is a solvent that has a high dielectric constant (ϵ ≥ 15); an...
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Chemical Shift: Internal References and Solvent Effects01:17

Chemical Shift: Internal References and Solvent Effects

In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Leveling Effect and Non-Aqueous Acid-Base Solutions02:11

Leveling Effect and Non-Aqueous Acid-Base Solutions

This lesson defines the leveling effect in acidic and basic solutions and its role in aqueous and non-aqueous solutions. It is essential to understand the competing nature of various species in a chemical system.
The Leveling Effect of a Solvent
A generic acid (HA) reacts with the generic base (B-) to yield the corresponding conjugate base (A-) and conjugate acid (HB):