Adhesion between prefabricated fiber-reinforced posts and different composite resin cores: a microtensile bond
Ziad Salameh1, Federica Papacchini, Hani F Ounsi
1Department of Dental Materials, University of Siena, Italy.
Purpose:
The aim of this study was to evaluate the bond strengths between various resin composites used as core materials (Multicore Flow, Ivoclar-Vivadent; Tetric Flow, Ivoclar-Vivadent; Filtek Flow, 3M-ESPE; Tetric Ceram, Ivoclar-Vivadent; Filtek Z250, 3M-ESPE), and an FRC post (FRC Postec Plus, Ivoclar-Vivadent) by means of the microtensile nontrimming technique.
Materials And Methods:
Five experimental groups were used. For the microtensile nontrimming technique, 45 to 50 beam-shaped specimens per group were obtained from cylinders of core material, which had been built up around the post by progressively adding small increments of composite resin. Each specimen was loaded in tension until failure at either one of the two post/core interfaces present in each stick. The differences in interfacial bond strength amongthe groups were tested for statistical significance with the one-way ANOVA test, followed by the Dunnett test for post-hoc comparisons.
Results:
The measured bond strengths in MPa were 17.29 +/- 6.02 for FRC+MultiCore Flow, 16.37 +/- 6.92 for FRC+Tetric Flow, 13.14 +/- 5.35 for FRC + Filtek Flow, 12.38 +/- 4.34 for FRC + Tetric Ceram, and 10.75 +/- 5.43 for FRC + Filtek Z250. The statistical analysis revealed that MultiCore Flow achieved significantly higher bond strengths than Filtek Flow (p = 0.03), Tetric Ceram (p < 0.001), and Filtek Z250 (p < 0.001). The bond strength of Tetric Flow was significantly higher than that of Filtek Z250 (p = 0.003).
Conclusion:
For core buildup on a fiber post, dual-cure composites appear to be preferable to light-curing composites.
Related Concept Videos
Bonding and Strength of Aggregate
Fiber Reinforced Concrete
Reinforcements in Concrete
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...