Related Experiment Video
Updated: Aug 8, 2026

Establishment of a Simple and Effective Rat Model for Intraoperative Parathyroid Gland Imaging
Published on: August 17, 2022
[Localisation of parathyroid glands using planar (99m)Tc-sestamibi scintigraphy. Comparison between subtraction- and
B Schommartz1, K Cupisti, C Antke
1Nuklearmedizinische Klinik, Universitätsklinikum Düsseldorf, Moorenstrasse 5, 40225 Düsseldorf. schommar@uni-duesseldorf.de
Aim:
In the context of presurgical localisation of parathyroid adenomas in primary hyper-parathyreoidism (pHPT) using (99m)Tc-sestamibi scintigraphy, subtraction- and dualphase technique are compared with each other and with the surgical findings.
Patients, Methods:
Prospectively, 126 patients with pHPT were investigated presurgically. For visualisation of parathyroid adenomas, an image of the thyroid ((99m)Tc-pertechnetat) was subtracted from a perfusion image ((99m)Tc-sestamibi) and 2 h p. i. another image was acquired for identification of retention of activity. Considering both techniques the clinical findings were reported promptly. Retrospectively, the evaluations were presented separately to four experienced raters.
Results:
In clinical routine for 109 patients correct findings were reported presurgically (87%). From 129 resected parathyroid adenomas 118 were localised correctly (sensitivity 91%, positive predictive value 94%). Concerning the retrospective analysis, in 75% of the cases both techniques provided the correct site, in 14% only the dual-phase technique and in 7% only the subtraction-technique was correct. With the help of the dual-phase technique significantly more investigations were correctly rated than with the help of the subtraction technique (88.7 +/- 3.2% vs. 81.6 +/- 1.2%, p < 0.01, two-sided t-test).
Conclusion:
The presurgical scintigraphic localisation of hyperactive parathyroid glands in pHPT assists minimal invasive surgery serving a high rate of correct findings. According to our data the dual-phase technique seems to be more sensitive than the subtraction technique. In some cases, however, the correct site may only be found using the subtraction technique. For an optimal surgical strategy we suggest the combination of both techniques.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
The Parathyroid Glands
Oxyphil cells, whose functions remain elusive, emerge during late puberty, adding a layer of complexity to the parathyroid gland's intricacies. In contrast, principal parathyroid cells undertake a vital role by producing...