Continuous-time monitoring of Landau-Zener interference in a cooper-pair box

Mika Sillanpää1, Teijo Lehtinen, Antti Paila

  • 1Low Temperature Laboratory, Helsinki University of Technology, FIN-02015 HUT, Finland.

Related Concept Videos

Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Zener Diodes01:16

Zener Diodes

Zener diodes are specialized semiconductor devices designed to operate in the reverse breakdown region, where they allow current to flow into the cathode, making it positive relative to the anode. This reverse operation distinguishes Zener diodes from conventional diodes and enables their use in various applications, most notably as voltage regulators. One of the defining characteristics of Zener diodes is their nearly vertical I-V (current-voltage) characteristic curve above a certain...
Schottky Barrier Diode01:27

Schottky Barrier Diode

Schottky barrier diodes are specialized semiconductor devices characterized by their unique construction. This construction involves combining a metal layer with a moderately doped n-type semiconductor material. This combination leads to the formation of a Schottky barrier, a pivotal element that defines the diode's operational characteristics. The core functionality of Schottky barrier diodes is their capacity to allow current to flow in only one direction due to their distinctive...
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists of...
Radial System Protection01:23

Radial System Protection

Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...