Related Experiment Video
Updated: Aug 8, 2026

Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
NexTemp thermometer can be used interchangeably with tympanic or mercury thermometers for emergency department use
1Department of Emergency Medicine, Freemasons Hospital, East Melbourne, Victoria, Australia. manirajee@hotmail.com
Objectives:
To determine the agreement between the chemical dot NexTemp thermometer with mercury and tympanic thermometers and the repeatability of measurements using these devices.
Methods:
A prospective study involving a convenience sample of 194 consenting adult patients presenting to the ED, Freemasons Hospital, East Melbourne, Victoria, Australia. A survey of emergency medical staff was conducted to determine what they considered an acceptable level of agreement and repeatability for a putative new thermometer. The NexTemp thermometer's performance was judged against this. For each thermometer, a set of two temperature measurements was made in every patient. The sequence of the set of readings (and hence device) was random between patients and the staff member performing one set was blinded to the results of the other two sets of readings in each patient. The method of Bland and Altman was used for assessing agreement and repeatability.
Results:
Clinicians considered that a new thermometer should exhibit repeatability of +/- 0.3 degrees C and agree with existing devices within +/- 0.5 degrees C. The tympanic thermometer had 95% limits of repeatability of -0.8-0.5 degrees C compared with the NexTemp (-0.3-0.4 degrees C) and mercury thermometers (-0.3-0.4 degrees C). The NexTemp thermometer agreed with mercury thermometer within -0.6-0.5 degrees C. The tympanic thermometer agreed with the mercury thermometer within -1.0-1.1 degrees C.
Conclusion:
Based on temperature measurement only, the NexTemp thermometer can be used interchangeably with current mercury and tympanic thermometers.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...