Rapid screening of polychlorinated biphenyls in sediments using non-equilibrium solid-phase microextraction and fast
R Montes1, M Ramil, I Rodríguez
1Departamento de Química Analítica, Nutrición y Bromatología, Instituto de Investigación y Análisis Alimentario, Universidad de Santiago de Compostela. Santiago de Compostela 15782, Spain.
Abstract:
A rapid method for the screening of polychlorinated biphenyls (PCBs) in sediment samples is described. Analytes are concentrated on a poly(dimethylsiloxane) (PDMS) solid-phase microextraction (SPME) fibre, separated using a narrow-bore gas chromatography column (10 m x 0.1mm I.D.) and determined with a micro-electron-capture detector (micro-ECD). The narrow-bore column showed a similar separation efficiency to a conventional capillary one (30 m x 0.32 mm I.D.) and allowed a 3 times reduction in the analysis time. Moreover, thermal desorption of SPME fibres in the narrow-bore column did not produce any degradation in the quality of separations when compared to the split injection mode. The use of an oxidative sample treatment was mandatory to remove sulphur interferences in the chromatograms and increase the yield of PCBs during SPME for short sampling times. Under optimised conditions, a fraction of sediment (0.1-0.5 g) was mixed with 5 ml of a 0.2M potassium permanganate solution and 0.5 ml of sulphuric acid 6M in a 22 ml closed vessel. Sample treatment and headspace SPME of PCBs were performed simultaneously for 10 min at 100 degrees C. Globally, the whole analytical procedure takes about 20 min and presents quantification limits between 0.5 and 1.3 ng/g. Accuracy was evaluated by analysing a reference sediment sample with certified concentrations of several PCBs.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Types of Detectors-II
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Ion-Exchange Chromatography