Related Experiment Video
Updated: Aug 8, 2026

Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Polyp measurement using CT colonography: agreement with colonoscopy and effect of viewing conditions on interobserver
David Burling1, Steve Halligan, Stuart Taylor
1Intestinal Imaging Centre, St. Mark's Hospital, Harrow, Middlesex, England HA1 3UJ.
Objective:
This article presents inter- and intraobserver agreement for estimates of polyp diameter using CT colonography, including the effects of different visualization displays and prior experience.
Materials And Methods:
Four observers, three of whom had prior experience with CT colonography, estimated the maximum diameter of 48 polyps using three different visualization displays: 2D colonography window, 2D abdominal window, and 3D surface rendering. Each re-measured a subset of 10 polyps. Polyps measured 2 to 12 mm according to a colonoscopic reference. Inter- and intraobserver agreement and agreement with the reference measurement were determined using the Bland-Altman method, paired Student's t testing, analysis of variance, and analysis of covariance (ANCOVA), and by calculating the components of variance.
Results:
CT measurements overestimated polyp diameter, a phenomenon found least using the 2D abdominal display. Generally, 95% limits of agreement encompassed different size categories for individual polyps: the widest spanned 14.6 mm (-4.6 mm to 10.0 mm) for an experienced observer using the 3D display. When using the 2D abdominal display, no significant difference was found between estimates and the reference value for the other two experienced observers (p = 0.83 and 0.23). All the observers' measurements were significantly different from the reference when using the 3D display (p < 0.001). The novice was significantly different from the experienced observers in some analyses. Inter- and intraobserver agreement were poorest for the 3D display.
Conclusion:
Measurement of polyp diameter from CT colonography is subject to variation contingent on the observer's experience and the viewing display used. Although 3D visualization display is commonly used for polyp detection, it should not be used for measurement.